Your Project EV or EVIQ charger may flash various LED lights on the front panel to indicate the status of your charger. Here are their meanings:
Pulsing Green: Your vehicle is fully charged.
Amber Light: Charger is in 'prepared' mode.
Continuous flashing red, 1 blink (Fault code: 105): The unit has detected an over voltage.
Continuous flashing red, 2 blinks (Fault code: 106): The unit has detected an under voltage.
Continuous flashing red, 3 blinks (Fault code: 100): The red emergency stop button is pressed or broken.
Continuous flashing red, 4 blinks (Fault code: 108): The unit has detected an overcurrent.
Continuous flashing red, 5 blinks (Fault code: 109): The unit has detected an over temperature.
Continuous flashing red, 6 blinks (Fault code: 110): The unit has detected a DC leakage current.
If you experience any of these issues, turning off the charger at the consumer unit and restarting it after a short time should resolve it. If the problem persists, please contact your charger manufacturer.